Home > News > Industry News > Park Cam achieves glass industry refractory success

Park Cam achieves glass industry refractory success

Post Time:Aug 31,2022Classify:Industry NewsView:1160

Park Cam recently operated a furnace at full capacity for 12 months with virtually zero wear in critical areas.

Park-Cam-PR-image_46527c80523046a5c0b3b8e30581599a(1).jpg

Working closely with PaneraTech, the Turkish glass producer was able to make data-driven decisions to target cooling and maximise the operation time before overcoating.

The furnace that achieved this milestone, Furnace 20, began its campaign in September 2013 at Park Cam’s Bozuyuk Glass Packaging production facility.

The company began a multi-year agreement with PaneraTech to monitor its furnace in 2018. SmartMelter radar technology was used to inspect the furnace at least twice per year.

After each inspection, the plant team discussed results and recommended actions with PaneraTech’s team. Because PaneraTech had created a digital model of the furnace, the teams could visually review the measurements of each refractory block.

PaneraTech was able to contribute insights from over half a million refractory measurements and make predictions based on that data.

Using this data as a guide, Park Cam increased cooling wind at critical blocks and monitored those areas closely to ensure safe operation. It also collected temperature data on a regular basis on these critical blocks. After each six-month scan, adjustments were made.

“We were able to have confidence in our decisions because of the data PaneraTech provided,” saidd Cetin EĞri Deputy General Manager of Park Cam. “Because of this, we could carefully manage risk and make good financial decisions at the same time.”

The industry typically overcoats when refractory thickness is 25 mm (1 inch). However, Park Cam was able to operate without overcoating an additional two years after reaching 25 mm.

Once the thickness reached 18 mm, the targeted cooling allowed the plant to operate 12 months with virtually no additional wear on these blocks. After this 12-month period, they decided to overcoat the refractory.

“Our experience with Park Cam is a testament to what we have known for a long time; that a manufacturer can run their sidewalls much longer than what they currently do once thicknesses reach critical level,” said Yakup Bayram, president of PaneraTech.

“We have seen the difference that data-driven decisions can make. This is why we have expanded our services to include a full Digital Furnace Monitoring programme. Park Cam’s approach has helped to lay the groundwork for this service.”

PaneraTech’s Digital Furnace Monitoring Programme includes SmartAudit, regular furnace audits that incorporate an 18-point radar spot check into the standard visual, thermal, and endoscopic evaluations.

New technology is also available as part of this programme, such as Polaris continuous monitoring sensors. Digital Endoscopy that uses laser technology will be available in 2023.

PaneraTech works with manufacturers to create a schedule of services for each year of the campaign life, and condition-based monitoring can be added on a narrow scope as necessary.

Learn more about this case study in the September issue of Glass International.

Source: https://www.glass-international.com/Author: shangyi

Hot News

返回顶部